N5500LW Data (RASP)
Accuracy of this data file:
|
This File |
Certified |
± |
Diameter |
98 mm |
98 mm |
= |
Length |
1,383 mm |
1,383 mm |
= |
Prop. Weight |
9,182 g |
9,182 g |
= |
Total Weight |
14,855 g |
14,855 g |
= |
Avg. Thrust |
5,258.1 N |
5,343.5 N |
−2% |
Max. Thrust |
6,653.0 N |
6,677.8 N |
= |
Total Impulse |
19,137.8 Ns |
19,137.0 Ns |
= |
Burn Time |
3.6 s |
3.6 s |
+2% |
Add this file to my outbox.
Data Graph
File Notes
Do you have a comment on this file?
Please add a note.
Raw Data
; raw data measured from tripoli cert.pdf via program ghostview.
;
; Loki N-5500-LW for the CTI Pro98 6GXL Case
;
N5500 98 1383 P 9.1820 14.8550 Loki
0.001 30.944
0.026 433.218
0.090 6652.990
0.155 6374.493
0.826 6219.772
1.239 6219.772
1.600 6281.660
1.703 6374.493
1.806 6312.604
2.000 6065.051
2.658 5693.722
2.826 5693.722
2.877 5508.057
2.994 3929.906
3.071 3063.470
3.110 2784.973
3.148 2661.196
3.174 2599.308
3.329 1825.704
3.355 1423.430
3.497 1113.989
3.523 959.268
3.535 1113.989
3.574 835.492
3.613 526.050
3.665 309.441
3.703 154.721
3.729 92.832
3.819 0.000
;
; Total Impulse 19137.98 (N-sec)
; Avg Thrust 5011.25 (N)
; Max Thrust 6652.99 (N) at 0.090 sec
; Specific Impulse 212.54 (Sec)
You can also download the raw data points as a CSV file.